The Energy Return and Closed Loop of Computing Civilization:

PACM-avatar-img
發佈於PACM 王者世代 個房間
更新 發佈閱讀 33 分鐘

Taiwan’s IDC Net-Zero Path

The Power Hunger of Data Centers

Data centers are rapidly becoming huge energy consumers. According to the IEA, in 2024 global data centers consumed about 415 terawatt-hours (TWh) of electricity—around 1.5% of world electricity[1]. This consumption has been growing roughly 12% per year. Under current trends, it could double by 2030 to about 945 TWh (near 3% of global electricity)[2]. In other words, the “data factories” that power our digital world are feeding on massive amounts of power. A single high-performance server can draw hundreds of watts; tens of thousands of GPUs running AI models generate heat equivalent to an entire city warming up. This computational power can be thought of as a new kind of “fire”: instead of burning coal or oil, it burns electricity. But in terms of energy and climate impact, it is still just as real. Every hour of AI training or inference consumes electricity and produces waste heat and CO₂ emissions.

Rapid AI adoption is a key driver. Specialized computing hardware (GPUs, TPUs, etc.) deployed for AI workloads significantly raises power demands. For example, recent analyses note that AI workloads account for about 5–15% of current data-center power use, and this share could grow to 35–50% by 2030[8]. In sum, our modern “cloud” is actually grounded in a voracious energy appetite. While we often regard data as “weightless” in the cloud, the reality is that data centers are very much bound to the physical world: they require vast land, electricity, and cooling resources. This creates what one might call an energy hunger: power companies expand substations, tech giants acquire land, and entire supply chains emerge – not for fuel, but for electrons.

Land, Cloud, and the New Paradigm

Every cloud server farm needs a foundation: land, power lines, water cooling, and infrastructure. The ground beneath data centers bears the burden of heat, exhaust, and water discharge. Traditional cooling towers expel hot vapor; conventional air conditioning uses fluorocarbon refrigerants that have huge global-warming potential. As AI models grow bigger, this burden on the environment intensifies. In effect, the progress of digital civilization and the stress on our planet become deeply linked. Data centers are no longer virtual heartbeats separate from the physical world, but rather physical energy factories that entwine with natural cycles.

For example, consider cooling: old-school chillers use lots of electricity to compress refrigerants, releasing both heat and greenhouse gases. They treat water as a free resource (for cooling towers) and carbon as an afterthought. As a result, traditional data centers pour heat into the atmosphere and send carbon out invisibly. The Tier X model challenges this. It treats cooling and energy as parts of a metabolic cycle, not just as waste output. In Tier X, waste heat is not thrown away but reused, and carbon is either neutralized or captured. In other words, land is not just a passive platform – it becomes part of the facility’s life support, helping to recycle energy and lock away carbon.

Tier X Data Centers: The Self-Sustaining Organism

Tier X is a new architecture for data centers that views them as living systems rather than static factories. Its guiding principle is energy metabolism: instead of the one-way model of “Input–Consume–Emit,” Tier X does “Absorb–Transform–Cycle–Replenish.” Concretely, a Tier X facility integrates several innovations:

  • Lithium-Bromide (LiBr) Absorption Cooling: Waste heat from servers (hot water) is fed into a LiBr absorption chiller, which uses heat to drive the refrigeration cycle. In practice, water (as refrigerant) is absorbed by a LiBr solution and then desorbed by low-grade steam or hot water. This produces chilled water at the servers without electric compressors[3]. The result is that cooling needs almost no extra electricity (saving on the order of 90%), and eliminates any HFC/F-gas refrigerants (global warming potential = 0). Essentially, Tier X “eats” its own heat: hot water drives the chiller, which produces cold water to cool the servers, in a closed loop. Cooling becomes part of the energy reclaim system rather than an energy burden.
  • Hydrothermal Conversion (“Wet Pyrolysis”): Farm waste, sewage, kitchen scraps, and even animal carcasses (e.g. from African swine fever culling) are fed into a high-pressure, high-temperature water reactor (typically 180–250°C, ~20 MPa)[4]. This hydrothermal carbonization process kills pathogens (bacteria, viruses, DNA) — studies have shown that 150°C for 30 minutes will eliminate most pathogens[5] — while breaking down wet biomass into three valuable products:

·      Syngas (gaseous fuel): A mix of hydrogen, carbon monoxide, methane, etc. This gas is directed to a Combined Cooling, Heating, and Power (CCHP) generator to produce electricity and usable heat.

·      Bio-oil (liquid fuel): A heavy tar-like organic oil rich in hydrocarbons. It can be burned to provide heat or upgraded into sustainable fuels (e.g. bio-diesel, aviation fuel). The system can route this oil through a dedicated burner or refinery process.

·      Hydrochar (solid biochar): A carbon-rich charcoal solid (70–80% fixed carbon). This material is remarkably stable in soil and can sequester carbon long-term. In fact, each ton of biochar can lock away roughly 2.5–3 tons of CO₂-equivalent[6]. The biochar is harvested and can be used as a soil amendment or stored as a permanent carbon sink.

By coupling these systems, Tier X data centers form an energy-heat-cool loop: servers generate waste heat → LiBr chiller uses that heat to make cooling → servers stay cool and run efficiently → any remaining heat drives the hydrothermal reactor → the reactor generates fuel and sequesters carbon → that fuel powers electricity and even more cooling. In effect, the data center “breathes”: it intakes resources (sun, wind, waste), processes them, and outputs useful work, heat, and stabilized carbon, rather than pollution. When energy flows through this system, nothing is simply wasted — carbon is either reused or stored.

AI EMS and Digital MRV: The Intelligent Brain

Such a complex metabolic data center needs a nervous system and brain. That role is played by the AI Energy Management System (AI EMS) and digital MRV (Measurement, Reporting, Verification). The AI EMS continuously monitors power generation (solar, wind, biogas), battery storage, cooling loads, and grid conditions, and makes minute-by-minute decisions to optimize the energy mix. For example, it predicts weather and load in the next few hours, then decides when to burn bio-oil versus drawing from batteries or letting solar feed the load, always aiming to minimize real-time carbon intensity. If the external grid is dirty (e.g. coal-heavy) at a given hour, the system can disconnect and run on internal clean sources (biogas, batteries). If renewables peak, it stores excess energy or drives more cooling. This turns the data center into a predictive, adaptive entity where energy use is constantly aligned with sustainability.

Meanwhile, digital MRV serves as the data center’s sensory feedback and memory. Instead of vague annual offsets, dMRV tracks every watt, every joule of energy and carbon in real time. It records exactly which energy sources are used each hour, how much waste heat is captured, how much bio-oil is burned versus upgraded, and how many kilograms of carbon are sequestered. All this information is logged (often on blockchain or verifiable ledgers) and can be audited. Crucially, this links operations directly to carbon accounting. The carbon captured in biochar or the emissions avoided by not using grid power become officially quantifiable. In fact, under IFRS Sustainability standards, a “carbon credit” is formally defined as an emission reduction or removal unit issued by a certified program[7]. In Tier X, the carbon permanently stored as biochar (or avoided by efficient cooling) can be issued as compliance credits (Article 6.4 ERs under the Paris Agreement). Instead of vague promises, the data center essentially generates its own bankable carbon credits. AI EMS and dMRV form a feedback loop: operations generate emissions data, the AI adjusts strategies, new carbon outcomes are recorded, and the process refines. The system gains a kind of “self-awareness” of its carbon footprint, ensuring it continuously shrinks it.

The Triple Sovereignty: Biosecurity, Energy, and Carbon Finance

Tier X weaves together a new governance paradigm. The data center becomes a node of biosecurity sovereignty, energy sovereignty, and carbon-finance sovereignty simultaneously. On biosecurity, the shift from burying or burning diseased waste to hydrothermal conversion is transformative: instead of passively disposing of hazardous biomass (like ASF-infected pigs), the facility proactively neutralizes pathogens and repurposes them as fuel[5]. This turns a public health crisis into a resource. On energy, the system’s internal loop means the facility barely depends on the external grid — city power lines become backup rather than lifeline. This is a form of energy sovereignty: the site’s own microgrid, fuel production, and storage ensure uninterrupted operation even if the grid falters or goes carbon-heavy. Finally, on carbon finance, digital MRV makes every stored carbon a tracked asset. Sequestered biochar yields monetizable carbon credits under international rules; even the efficiency gains from cooling translate into documented emission reductions. In short, the data center issues its own “carbon currency,” giving it weight in global climate markets. These three sovereign layers buttress each other: bio-waste fuels energy autonomy, energy autonomy enables carbon capture, and carbon capture funds the system’s value. It’s a closed loop of technology and governance: biosecurity data feeds the energy system; energy operations follow carbon-accounting rules; and carbon credits reinforce biosecurity and energy stability.

A New Computing Civilization Takes Root

In Tier X, computing no longer floats untethered in a metaphorical cloud. Instead, it lands on the earth and begins to co-evolve with nature. Solar panels, wind turbines, and biowaste digesters pulse in rhythm; waste heat, cooling, and carbon form a balanced feedback cycle. Data centers become part of the ecosystem, not outside it. The era of treating electricity and cooling as endless, cost-free inputs is ending. Instead, every kilowatt is traced, every joule is recycled or stored, and every carbon atom is given a final destination. This is not just an engineering achievement but a philosophical shift: technology acknowledges its dependence on the planet and acts responsibly. For Taiwan’s data centers, Tier X offers a path from being massive power consumers to becoming contributors to climate stabilization. It means employing computing power to understand climate, and in turn embedding digital processes into natural cycles. The road from fire (coal and oil) to water (hydrothermal conversion) symbolizes how our energy story turns from conquest to symbiosis. Carbon finds two homes now: it can either release and flow through the data center (supporting its operations) or be buried in the soil as char. In this vision, data are not just bits in a server; they are the gentle flow of energy in balance. Tier X is more than a data center – it’s a template for a breathing, living energy civilization, where computation and earth form an ethical partnership.

References: Global data-center energy statistics[1][2][8]; HTC pathogen kill[5]; HTC process[4]; biochar sequestration[6]; LiBr cooling use of waste heat[3]; IFRS carbon-credit definition[7].


[1] [2] Energy demand from AI – Energy and AI – Analysis - IEA

https://www.iea.org/reports/energy-and-ai/energy-demand-from-ai

[3] Steam Tip 14: Use Low-Grade Waste Steam to Power Absorption Chillers - Campbell Sevey

https://www.campbell-sevey.com/steam-tip-14-use-low-grade-waste-steam-to-power-absorption-chillers/

[4] Hydrothermal Carbonization: Upgrading Waste Biomass to Char | Ohioline

https://ohioline.osu.edu/factsheet/fabe-6622

[5] FSE-17018-DTF 1..8

https://www.ars.usda.gov/ARSUserFiles/60820500/Manuscripts/2017/man1022.pdf

[6] Overview of Carbon Removal: Focus on Biochar

https://www.mtstonegate.com/post/overview-of-carbon-removal-focus-on-biochar

[7] Greenhouse Gas Emissions Disclosure requirements applying IFRS S2 Climate-related Disclosures

https://www.ifrs.org/content/dam/ifrs/supporting-implementation/ifrs-s2/ghg-ifrs-s2-educational-material.pdf

[8]  AI: Five charts that put data-centre energy use – and emissions – into context - Carbon Brief

https://www.carbonbrief.org/ai-five-charts-that-put-data-centre-energy-use-and-emissions-into-context/

留言
avatar-img
留言分享你的想法!
avatar-img
PACM 陋室說書
11會員
191內容數
合規碳信用 : 國際規則 → 各國制度 → 市場轉型! 合規碳信用的發展路徑,是從《巴黎協定》第六條的國際規則出發,由各國立法制度化,最終推動市場從自願性信用轉向合規信用。未來能真正「抵稅、履約、計入國家帳本」的碳信用,只會是合規體系下的產品。
PACM 陋室說書的其他內容
2025/11/03
全球算力需求與能源壓力 隨著人工智慧與雲端運算爆發,全球資料中心的電力需求急劇上升。國際能源署(IEA)報告指出,2024年資料中心用電量約415 TWh(約占全球電力1.5%),預計到2030年將增至945 TWh(接近全球電力的3%)[1]。另一方面,麥肯錫分析更估計全球資料中心用電到2030
2025/11/03
全球算力需求與能源壓力 隨著人工智慧與雲端運算爆發,全球資料中心的電力需求急劇上升。國際能源署(IEA)報告指出,2024年資料中心用電量約415 TWh(約占全球電力1.5%),預計到2030年將增至945 TWh(接近全球電力的3%)[1]。另一方面,麥肯錫分析更估計全球資料中心用電到2030
2025/11/03
當全球碳市場已進入《巴黎協定》第六條合規體系(PACM)時代,日本與瑞士都以 IA 與 ITMO 打通主權帳本,東盟更走向 RWA 金融化,而台灣卻還在能源展上宣傳 Verra 可抵換。這不只是誤會,而是一場"錯世代"的制度迷航。 【個人觀察/PACM】 我在 「台灣國際智慧能源週(Energ
Thumbnail
2025/11/03
當全球碳市場已進入《巴黎協定》第六條合規體系(PACM)時代,日本與瑞士都以 IA 與 ITMO 打通主權帳本,東盟更走向 RWA 金融化,而台灣卻還在能源展上宣傳 Verra 可抵換。這不只是誤會,而是一場"錯世代"的制度迷航。 【個人觀察/PACM】 我在 「台灣國際智慧能源週(Energ
Thumbnail
2025/11/03
這是一段橫跨工程、防疫與哲學的能源實驗。作者以 Tier X 架構打造一座能「發電、製冷、封碳」的資料中心,核心技術是水熱裂解與溴化鋰吸收式製冷,目標是實現24/7/365無碳能源、三聯供循環,並將碳封存量體轉化為合規碳信用,象徵臺灣資料中心邁入「能源主權 × 碳金融主權 × 防疫主權」時代。
Thumbnail
2025/11/03
這是一段橫跨工程、防疫與哲學的能源實驗。作者以 Tier X 架構打造一座能「發電、製冷、封碳」的資料中心,核心技術是水熱裂解與溴化鋰吸收式製冷,目標是實現24/7/365無碳能源、三聯供循環,並將碳封存量體轉化為合規碳信用,象徵臺灣資料中心邁入「能源主權 × 碳金融主權 × 防疫主權」時代。
Thumbnail
看更多
你可能也想看
Thumbnail
話說身為短線交易者,每天要作的事情就是從盤勢觀察、到籌碼流向,再到經過多維度資料數據交叉比對,盤中盯著分K、江波圖和五檔報價,算計著每一分K線的轉折,雖能換來即時驗證判斷的快感與成就,但長期下來,卻也衍生眼睛與肩頸卻成了抹不去的職業病。
Thumbnail
話說身為短線交易者,每天要作的事情就是從盤勢觀察、到籌碼流向,再到經過多維度資料數據交叉比對,盤中盯著分K、江波圖和五檔報價,算計著每一分K線的轉折,雖能換來即時驗證判斷的快感與成就,但長期下來,卻也衍生眼睛與肩頸卻成了抹不去的職業病。
Thumbnail
本專欄將提供給您最新的市場資訊、產業研究、交易心法、精選公司介紹,以上內容並非個股分析,還請各位依據自身狀況作出交易決策。歡迎訂閱支持我,獲得相關內容,也祝您的投資之路順遂! 每年 $990 訂閱方案👉 https://reurl.cc/VNYVxZ 每月 $99 訂閱方案👉https://re
Thumbnail
本專欄將提供給您最新的市場資訊、產業研究、交易心法、精選公司介紹,以上內容並非個股分析,還請各位依據自身狀況作出交易決策。歡迎訂閱支持我,獲得相關內容,也祝您的投資之路順遂! 每年 $990 訂閱方案👉 https://reurl.cc/VNYVxZ 每月 $99 訂閱方案👉https://re
Thumbnail
外媒報導台灣缺電問題恐成全球晶片業變數,經濟部長郭智輝今天表示,目前電力充足;至於 AI 新增用電評估是經過「精準計算」,以目前估算結果來看,準備電量亦足夠。
Thumbnail
外媒報導台灣缺電問題恐成全球晶片業變數,經濟部長郭智輝今天表示,目前電力充足;至於 AI 新增用電評估是經過「精準計算」,以目前估算結果來看,準備電量亦足夠。
Thumbnail
摘要重點 1.下修全年除記憶體外半導體營收年成長至約 10%,晶圓代工至mid~high teens,維持台積電全年營收年增 low~mid twenties。維持全年資本支出不變。
Thumbnail
摘要重點 1.下修全年除記憶體外半導體營收年成長至約 10%,晶圓代工至mid~high teens,維持台積電全年營收年增 low~mid twenties。維持全年資本支出不變。
Thumbnail
臺灣北部一家重要發電廠的多個故障幾乎導致半數人口失去電力即時面臨的嚴重風險。臺灣電力網容易受自然災害和外部威脅影響,政府需提高電力網的韌性,優先發展可再生能源。
Thumbnail
臺灣北部一家重要發電廠的多個故障幾乎導致半數人口失去電力即時面臨的嚴重風險。臺灣電力網容易受自然災害和外部威脅影響,政府需提高電力網的韌性,優先發展可再生能源。
追蹤感興趣的內容從 Google News 追蹤更多 vocus 的最新精選內容追蹤 Google News